GL Gamma EC

Centrifugal Roof Mounted Exhaust Fans

  • EC motor features reverse polarity protection, locked rotor protection and soft start.
  • No additional protection such as contactors are required.
  • Can be pre-configured to suit specific sensors and applications, and are supplied standard with 0-10V control input.
  • A full range of sensors are available including differential pressure, humidity, temperature, air velocity and pollutant.
  • Can be run as an independent ventilation source or integrated into most building management systems.
  • Robust, galvanised steel housing and cowl.
  • Quick release toggle clamps provide easy access for cleaning and maintenance.
  • Can be mounted at angles up to 30°.

SKU: EFAP-19

Quantity

Got a question about this product?

Email us or call us on +603 7846 0340 (Malaysia) or +91 33-24988126 (India)

Compatible Accessory Ranges

Please refer to Product Overview in Downloads for accessory size guide

CBD – Backdraft Shutters

CBD – Backdraft Shutters

EC Controller – 0-10V EC Speed Controller

EC Controller – 0-10V EC Speed Controller

Overview

The GL Gamma EC Series of centrifugal roof mounted exhaust fans incorporate the latest state of the art, energy saving EC motor technology. They feature integrated infinitely variable speed control and eliminate the need for external VSDs, current overloads and motor phase protection. The units are available in 315, 355, 450, 560 and 630mm fan sizes.

Features and Benefits

Design

The compact and low profile GL Gamma EC Series is a simple “plug and play” system which means installers do not need to have specialised control programing knowledge. They are suited to ducted vertical exhaust applications, include a removable windband that provides easy access for cleaning and maintenance.

Sensors

Matching sensors can easily be connected to monitor the ambient conditions in a space and provide real time feedback to the fan. The fan’s on-board microprocessor can adjust the speed and therefore modulate the ventilation rate to match the specific requirements of the area.

Protection

Integral thermal overload protection is supplied as standard.

Testing

All units are tested to ISO 5801:2007 (airside performance) and ISO 3744:2010 (sound performance).

Specification

Construction

The cowl is a vertical discharge design and manufactured from galvanised steel. Steel components shall be corrosion protected. The windband incorporates a quick-release toggle clamps to provide easy access for cleaning and maintenance.

Impellers

Impellers shall be made from high performance composite material. Backward-curved centrifugal design.

Motor

The fans are built with electronic commutated (EC) motors with sealed for life ball bearings. The motor requires an electricity supply of 200-277V single-phase, 50/60Hz for 315 to 450mm sizes. Electricity supply of 380-480V three-phase, 50/60Hz is required for 560 and 630mm sizes. Maximum ambient temperature is 60°C CDEC56VGL cannot exceed 16.8r/s at 60°C

Control

Integrated EC-Controller providing infinite speed control.

Additional Information

Backdraft shutters are an optional extra. The pressure loss across the shutter has to be added to the system pressure before making selections. All GL Gamma EC models can be pre-configured to suit specific sensors and specific applications. Please advise Elta Fans of these parameters at the time of order. EC motors should be directly connected to their appropriate AC supply. EC motors should not be regularly power cycled.

Typical Applications

Canteens and Food Courts
Canteens and Food Courts
Hospitals and Hospices
Hospitals and Hospices
Laboratories
Laboratories
Dental Surgeries
Dental Surgeries
Veterinary Clinics
Veterinary Clinics
Mortuaries
Mortuaries
Care and Nursing Homes
Care and Nursing Homes
Operating and Mobile Theatres
Operating and Mobile Theatres
Pharmacies
Pharmacies
Schools
Schools
Colleges and Universities
Colleges and Universities
Nurseries
Nurseries
Mobile Classrooms
Mobile Classrooms
Student Accommodation
Student Accommodation
Libraries and Archives
Libraries and Archives
Dark Rooms
Dark Rooms
Fast Food Outlets
Fast Food Outlets
Commercial Kitchens
Commercial Kitchens
Restaurants and Bars
Restaurants and Bars
Fire and Police Stations
Fire and Police Stations
Law Courts
Law Courts
Places of Worship
Places of Worship
Government Buildings
Government Buildings
Prisons and Detention Centres
Prisons and Detention Centres
Town Halls and Community Centres
Town Halls and Community Centres
Airport Terminals
Airport Terminals
Train and Bus Stations
Train and Bus Stations
Theatres
Theatres
Gyms
Gyms
Sports Centres
Sports Centres
Swimming Pools
Swimming Pools
Stadiums and Arenas
Stadiums and Arenas
Cinemas
Cinemas
Bowling Alleys
Bowling Alleys
Ice Rinks
Ice Rinks
Go Karting Tracks
Go Karting Tracks
Indoor Play Centres
Indoor Play Centres
Theme Parks
Theme Parks
Spas
Spas
Museums and Galleries
Museums and Galleries
Supermarkets
Supermarkets
Shopping Centres
Shopping Centres
Departmental Stores
Departmental Stores
Banks
Banks
Laundrettes and Dry Cleaners
Laundrettes and Dry Cleaners
Petrol Stations
Petrol Stations
Car Showrooms
Car Showrooms
Nail and Beauty Salons
Nail and Beauty Salons
Call Centres
Call Centres
Portable and Temporary Offices
Portable and Temporary Offices
Telecoms Buildings
Telecoms Buildings
Office Buildings
Office Buildings
TV and Recording Studios
TV and Recording Studios
Interested? Make an Enquiry

Customers Also Viewed

CBD – Backdraft Shutters

CBD – Backdraft Shutters

EC Sensors – Air Velocity Sensors
EC

EC Sensors – Air Velocity Sensors

EC Sensors – Controller with Infrared Sensor
EC

EC Sensors – Controller with Infrared Sensor

EC Sensors – Differential Pressure Switch
EC

EC Sensors – Differential Pressure Switch